cropped-LOGO_small.pngcropped-LOGO_small.pngcropped-LOGO_small.pngcropped-LOGO_small.png
  • Company
    • About Antron
    • Why Choose Us
    • Announcement
    • Certification
    • Patent
    • Awards
    • Latest News
  • Products
    • Emergency LED Driver
    • Emergency Lighting Inverter
    • GaN Power
    • LED Driver
    • Fluorescent Ballast
    • UV Ballast
  • Resources
    • Product Quick Search
    • Model Numbering System
    • Product Demo
    • APP Download
    • E-catalog
    • Technology Notes
  • FAQ
  • Contact Us
  • English
    • 繁體中文
✕

Products

  • Home
  • Emergency LED Driver
  • Constant Power Emergency LED Pack
  • Ultra High Voltage series
  • Constant Power Emergency LED Driver
Emergency Lighting Automatic Load Control Relay
2026-04-17
Triac Dimmable LED Driver CC
2026-04-27
Constant Power Emergency LED Driver

Constant Power Emergency LED Driver

✔ True Constant Power Output

✔ Universal Driver Compatibility

✔ Wide Input Voltage (120–480VAC)

✔ 90-Minute Emergency Backup

✔ Long-Life LiFePO₄ Battery

✔ Comprehensive Protection

✔ Integrated Test Function

✔ UL & CEC Certified

✔ 5-Year Warranty

Categories: Constant Power Emergency LED Pack, Emergency LED Driver, Ultra High Voltage series
Share
  • Description
  • Spec Sheets

Features

1. Definition and Core Mechanism of Constant Power (CP) Technology

In commercial life safety infrastructures, maintaining a reliable light output during an emergency evacuation is critical. Conventional emergency backup packs typically exhibit a declining power curve; as the internal battery discharges, the output wattage drops, causing the connected LED fixture to dim over time.
A Constant Power Emergency LED Driver (CP EMB) resolves this systemic issue through an active micro-regulated feedback loop. Regardless of the battery’s varying voltage state during discharge, the internal DC inverter dynamically adjusts the current output to deliver a rock-solid, stable wattage—ranging from 10W to 20W—throughout the entire emergency cycle.

2. Technical Engineering Advantages & Circuit Compatibility

Antron’s Constant Power Emergency Series features a forward-thinking electrical design tailored for modern solid-state lighting topologies:

  • Linear Voltage Adaptability: Engineered with a wide 15–55VDC Class 2 output voltage rating, making it universally compatible with a vast array of mid-to-high power LED modules without risking overvoltage damage.
  • High Driver Interoperability: Operates seamlessly as a shunt or bypass alongside any standard AC LED driver that features a maximum output current up to 5.0 Amperes.
  • Simplified Egress Calculations: Because the output wattage remains perfectly linear (e.g., exactly 10W or 20W), architectural specifiers can easily calculate the emergency lumen-per-watt (lm/W) performance, ensuring precise adherence to local emergency lighting lux requirements.

3. Industrial Specifications & Life Safety Compliance

Technical Parameter Specification Details B2B Project & Sourcing Value
Input Voltage Range Universal 120–277VAC to Wide 120–347VAC Globally adaptive; ideal for standard US grids and robust 347V Canadian industrial lines.
Emergency Output Power 10 Watts / 20 Watts (Constant) Guarantees un-decayed, stable fixture brightness during utility failures.
Output Voltage Range 15–55 VDC (Class 2 Compliant) Safe, low-voltage operation that simplifies fixture integration and approvals.
Battery Chemistry Premium Lithium Iron Phosphate (LiFePO4) Excellent thermal stability, environment-friendly, and extended lifecycle.
Emergency Runtime Minimum 90 Minutes Fully satisfies and exceeds UL 924 and NFPA 101 code requirements.
Certifications UL Listed, BC Certified, CEC Title 20 Approved Friction-free inspection sign-offs for commercial construction tenders.

4. Automatic Seamless Transfer and Maintenance Framework

The Antron emergency assembly contains an integrated solid-state automatic transfer switch linked to its LiFePO4 battery system:

  1. Grid Failure State: The unit instantly detects utility power cessation and switches the fixture to emergency mode via the internal DC inverter.
  2. Power Restoration State: Automatically transitions back to standby/charging mode, utilizing an optimized algorithm to preserve battery longevity.
  3. Routine Code Testing: Every kit includes an illuminated bi-color LED test switch. A solid LED indicates a healthy charging state. Facility managers can simulate an emergency grid failure instantaneously by pressing the indicator button, enabling effortless monthly (30-second) and annual (90-minute) mandatory life safety field tests.

Product Specification
Nominal Voltage(15-55V)Standard Series

Model NameVoltage VAC(Input )Power W (Output)Current mA(Output)Voltage V (Output)Metal ConduitDimension(mm)File
EMAP10-55 5120-2775333-9115-55Optional241*43*29.5Download
EMAP10-55120-27710670-18015-55Optional241*43*29.5Download
EMAP14-55120-27714935-25015-55Optional304*43*30.5Download
EMAP20-55 16120-277161060-29015-55Optional338*62*38Download
EMAP20-55120-277201350-36015-55Optional338*62*38Download
EMAP30-55 25120-277251666-45415-55Optional338*62*38Download
EMAP30-55120-277302000-54515-55Optional338*62*38Download
EMMP10-55120-34710370-18015-55Optional241*43*295Download
EMMP14-55120-34714935-25015-55Optional304*43*30.5Download
EMMP20-55 16120-347161350-36015-55Optional338*62*38Download
EMMP20-55120-347201350-36015-55Optional338*62*38Download
EMMP30-55 25120-347251666-45415-55Optional338*62*38Download
EMMP30-55120-347302000-54515-55Optional338*62*38Download
EM4P10-55347-48010670-18015-55Optional241*43*29.5Download
EM4P20-55347-480201350-36015-55Optional338*62*38Download
EM4P30-55 25347-480251666-45415-55Optional338*62*38Download
EM4P30-55347-480302000-54515-55Optional338*62*38Download

Nominal Voltage(15-55V)Special Series
Model Name Voltage VAC(Input)Power W(Output)Current mA(Output)Voltage V (Output)RemarkDimension(mm)File
EMAP10-55 120-2775333-9115-55Low Profile / Slim Type421.6*30*25.4/420*30.5*28Download
EMAP10-55120-27710670-18015-55Low Profile421.6*30*25.4Download
EMAP14-55120-27714935-25015-55Low Profile421.6*30*25.4Download
EMMP10-55120-3474267-7315-55Low Profile421.6*30*25.4Download
EMMP10-55120-34710670-18015-55Slim Type420*30.5*28Download
EMMP10-55120-34710670-18015-55Low Profile421.6*30*25.4Download
EMMP14-55120-34714935-25015-55Low Profile421.6*30*25.4Download

High Voltage(30-130V) Standard Series
Model Name Voltage VAC(Input)Power W(Output)Current mA(Output)Voltage V (Output)Metal ConduitDimension(mm)File
EMAP10-130120-27710333-7730-130Optional304*43*30.5Download
EMAP20-130 14120-27714467-10830-130Optional338*62*38Download
EMAP20-130120-27720667-15430-130Optional338*62*38Download
EMAP30-130 25120-27725833-19230-130Optional338*62*38Download
EMAP30-130120-277301000-23130-130Optional338*62*38Download
EMMP20-130120-34720667-15430-130Optional338*62*38Download
EM4P20-130347-48020667-15430-130Optional338*62*38Download

 

 

Our engineering and sales teams are always ready to support you. Antron provides OEM, ODM, and OBM services, and we are fully prepared to take on any challenges.

CUSTOM MENU

  • Company
  • Products
  • Resources
  • FAQ
  • Contact Us

COMPANY INFORMATION

TEL: +886-6-726-3906
FAX: +886-6-726-3908
Email: info@antron.com.tw
Adress: No.17-14 Lai-Kan Liaw, Hi-Chien Li, Jiali District, Tainan City, Taiwan 722012

Copyright © 2026 - Antron Electronics All rights reserved.
      載入迴響中...