cropped-LOGO_small.pngcropped-LOGO_small.pngcropped-LOGO_small.pngcropped-LOGO_small.png
  • Company
    • About Antron
    • Why Choose Us
    • Announcement
    • Certification
    • Patent
    • Awards
    • Latest News
  • Products
    • Emergency LED Driver
    • Emergency Lighting Inverter
    • GaN Power
    • LED Driver
    • Fluorescent Ballast
    • UV Ballast
  • Resources
    • Product Quick Search
    • Model Numbering System
    • Product Demo
    • APP Download
    • E-catalog
    • Technology Notes
  • FAQ
  • Contact Us
  • English
    • 繁體中文
✕

Products

  • Home
  • Emergency LED Driver
  • Constant Current Emergency LED Pack
  • Nominal Voltage series
  • NV CC Standard Version
  • Constant Current Emergency – LED Driver
Constant Current Emergency LED Driver
2026-03-26
LAEMAP10-EX55
Cold Pack Emergency LED Driver
2026-04-15
Constant Current Emergency -  LED Driver
Constant Current Emergency -  LED Driver - Image 2
Constant Current Emergency -  LED Driver - Image 3
Constant Current Emergency -  LED Driver - Image 4
Constant Current Emergency -  LED Driver - Image 5
Constant Current Emergency -  LED Driver - Image 6
Constant Current Emergency -  LED Driver - Image 7

Constant Current Emergency – LED Driver

● Universal input voltage 120-277, 120-347Vac
● At least 90 minutes in emergency mode
● Emergency pack is compatible with any AC driver
● High quality LiFePO4 battery inside
● Open/Short/Over-Voltage/Over Temp. protection
● Suitable for UL dry and damp location
● UL listed and CEC title 20 approval
● 5 years warranty
Categories: Constant Current Emergency LED Pack, Emergency LED Driver, Nominal Voltage series, NV CC Special Version, NV CC Standard Version
Share
  • Description
  • Spec Sheets

Features

1. Technical Definition and Operational Mechanism of Constant Current (C.C.) EMBs

In commercial and industrial solid-state lighting (SSL) infrastructures, maintaining electrical stability during power anomalies is paramount. A Constant Current Emergency LED Driver (C.C. EMB) is a specialized life-safety component engineered to regulate a precise, uninterrupted output current to the LED array when standard AC utility power fails.
Unlike voltage-regulated or fixed-wattage packs, a current-regulated system directly monitors and stabilizes the current through the LED junction. This technology mitigates thermal runaway risks and guarantees constant luminous flux without overdriving the light-emitting diodes, ensuring total compliance with international safety mandates like NFPA 101.

2. Multi-Range Forward Voltage Matching & High Circuit Compatibility

Different architectural lighting fixtures—such as LED panels, troffers, vapor-tights, wall packs, and linear luminaires—utilize varied circuit topologies requiring different forward voltages. Antron solves this integration bottleneck by offering three distinct DC output voltage ranges:

  • 15–55 VDC Range: Optimized for low-voltage, Class 2 compliant fixtures (e.g., standard LED panels and troffers), focusing on maximum installer safety.
  • 80–130 VDC Range: Tailored for mid-voltage commercial luminaires and architectural downlights.
  • 80–176 VDC Range: Engineered for high-voltage linear systems, high-bays, and robust vapor-tight industrial fixtures.
  • AC Driver Interoperability: This high versatility allows the backup unit to co-exist with any standard AC LED driver featuring a maximum output current up to 5.0 Amperes, operating as an un-intrusive bypass during standard grid operations.

3. Comprehensive Technical Specifications & Global Approvals

Technical Parameter Specification Details B2B Project Sourcing Value
Input Voltage Compatibility >Universal 120–277VAC to Wide 120–347VAC Globally adaptive; fully compatible with standard US commercial and 347V Canadian industrial grids.
Output Voltage Config. 15-55V (Class 2) / 80-130V / 80-176VDC Solves forward voltage mismatch; fits panel, linear, and high-voltage setups.
Battery Infrastructure Premium Lithium Iron Phosphate (LiFePO4) Superior thermal stability, ecofriendly chemistry, and extended operational lifecycles.
Emergency Runtime Minimum 90 Minutes Guaranteed Exceeds standard life safety evacuation duration criteria.
Regulatory Approvals UL Listed, BC Certified, CEC Title 20 Compliant Ensures smooth building inspection sign-offs and local government mandate alignment.

4. Automatic Seamless Transfer & Ground-Level Safety Maintenance

The integrated circuitry utilizes a solid-state automatic transfer module paired with a high-efficiency DC inverter:

  1. Grid Disruption Mode: Instantly registers utility power cessation, automatically forcing the driver to route energy from the enclosed LiFePO4 battery to the DC inverter, maintaining a steady constant current output.
  2. Grid Restoration Mode: Automatically transitions back to standard monitoring and trickle-charging mode once AC power stabilizes.
  3. Routine Code Testing: Every kit includes an illuminated test switch with an integrated status indicator (solid illumination signifies correct charging). Facility managers can trigger the mandatory monthly (30-second) and annual (90-minute) life safety tests by simply pressing the indicator, streamlining maintenance workflows.

Product Specification
Standard Series Nominal Voltage

Model NameVoltage V(Input)Power W(Output)Current mA(Output)Voltage V(Output)Metal ConduitDimension mmFile
EMAC10-55 5120-27759115-55Optional241*43*29.5Download
EMAC10-55120-2771019015-55Optional241*43*29.5Download
EMAC20-55 16120-2771629015-55Optional338*62*38Download
EMAC20-55120-2772038015-55Optional338*62*38Download
EMAC30-55 25120-2772545515-55Optional338*62*38Download
EMAC30-55120-2773054515-55Optional338*62*38Download
EMMC10-55120-3471019015-55Optional241*43*29.5Download
EMMC20-55120-3472038015-55Optional338*62*38Download

Special Series Nominal Voltage
Model NameVoltage VAC(Input)Power W(Output)Current mA(Output)Voltage V(Output)Metal ConduitDimension (mm)File
EMAC10-55 4120-27747215-55Slim Type420*30.5*28Download
EMAC10-55 10120-2771019015-55Slim Type420*30.5*28Download

High Voltage(80-130V)Standard Series
Model NameVoltage V(Input)Power W(Output)Current mA(Output)Voltage V(Output)Metal ConduitDimension mmFile
EMAC8-130120-27787080-130Optional241*43*29.5Download
EMAC28-130120-2772823080-130Optional338*62*38Download
EMMC8-130120-34787080-130Optional241*43*29.5Download
EMMC28-130120-3472823080-130Optional338*62*38Download

High Voltage(80-130V)Special Series
Model NameVoltage V(Input)Power W(Output)Current mA(Output)Voltage V(Output)Metal ConduitDimension mmFile
EMAC8-130120-27787080-130Slim Type420*30.5*28Download
EMMC8-130120-34787080-130Slim Type420*30.5*28Download

Ultra High Voltage(80-176V)Standard Series
Model NameVoltage V(Input)Power W(Output)Current mA(Output)Voltage V(Output)Metal ConduitDimension mmFile
EMAC8-176120-27784780-176Optional241*43*29.5
EMAC28-176120-2772816880-176Optional338*62*38
EMMC8-176120-34781780-176Optional241*43*29.5
EMMC28-176120-3472816880-176Optional338*62*38

LED Driver OEM/ODM Solutions for Global Brands.
Engineering, manufacturing and responsive support for lighting power projects.

Explore

  • Company
  • Products
  • Resources
  • FAQ
  • Contact Us

COMPANY INFORMATION

Tel: +886-6-726-3906
Fax: +886-6-726-3908
Email: info@antron.com.tw
Address: No. 17-14 Lai-Kan Liaw, Hi-Chien Li, Jiali District, Tainan City, Taiwan 722012

Copyright © 2026 - Antron Electronics All rights reserved.
      載入迴響中...